Model PD
Low Initial Cost, 80% Thermal Efficiency Gravity Vented 12 Propeller Models and 11 Browser Models Small Vent-Sizes Provide Lower Cost Available with Intermittent Pilot Ignition Power Exhaust Optional
 www.modine.com |
 |
|
 |
|
|
Model BD
Low Initial Cost, 80% Thermal Efficiency Gravity Vented 12 Propeller Models and 11 Browser Models Small Vent-Sizes Provide Lower Cost Available with Intermittent Pilot Ignition Power Exhaust Optional
 www.modine.com |
 |
|
 |
|
|
Model PDP
80% Thermal Efficiency Rotating Power Exhaust Horizontal or Vertical Venting Field-Convertible to Propane Field-Adjustable Level Hanging Intermittent Pilot Ignition, 100% Shut-off with Continiuos Retry
 www.modine.com |
 |
|
 |
|
|
Model BDP
80% Thermal Efficiency Rotating Power Exhaust Horizontal or Vertical Venting Field-Convertible to Propane Field-Adjustable Level Hanging Intermittent Pilot Ignition, 100% Shut-off with Continiuos Retry
 www.modine.com |
 |
|
 |
|
|
Model PSH
80% Sesonal Efficiency 82% Thermal Efficiency Horizontal or Vertical Venting 20% + Fuel Savings Versus Gravity-Vented Products 100% Outside Air for Combustion Stainless-Steel Secondary Heat-Exchanger Tubes Sealed Compartment Protects Combination Gas Control, Ignition Control, Manifold and Burner Horinzontal or Vertical Concentric Venting
 www.modine.com |
 |
|
 |
|
|
Model BSH
80% Sesonal Efficiency 82% Thermal Efficiency Horizontal or Vertical Venting 20% + Fuel Savings Versus Gravity-Vented Products 100% Outside Air for Combustion Stainless-Steel Secondary Heat-Exchanger Tubes Sealed Compartment Protects Combination Gas Control, Ignition Control, Manifold and Burner Horinzontal or Vertical Concentric Venting
 www.modine.com |
 |
|
 |
|
|
Model MT
High Intensity Model MT 13 Models Available 27,500 to 160,000 Btu/Hr Input Simple Chain Mounting High Heat Transfer Diamond-Faced Ceramic Tiles Unvented Operation Low Installation Chart Ideal for Spot Heating Available in Natural or Propane Gas
 www.modine.com |
 |
|
 |
|
|
Model DFG
Low Initial Cost Applications Cover Heating and/or Make-up Air 75,000 to 45, 000 Btu/Hr Input Capacity Low Maintenance Easy to Service
 www.modine.com |
 |
|
 |
|
|
Model HS
Totally-Enclosed Motor Thermal Overload Protection Adjustable Horizontal Blades Top/Bottom Inlet/Outlet Piping Built-in Fan Safety Guard
 www.modine.com |
 |
|
 |
|
1 | 2 |
Indoor Separated Combustion DFS, DBS, DCS
For Heating, Heating/Ventilating/Cooling and Make-Up Air Systems
The indoor separated combustion duct furnaces with blower, and/or cooling sections was designed for use with a building’s heating, heating/ventilating/cooling and make-up air systems. Separated combustion duct furnaces are specifically designed for buildings with hostile atmospheric conditions, such as high humidity or negative pressures. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas. The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others.
 www.modine.com |
 |
|
 |
|
1 | 2 |
Outdoor Gravity and power exhausted "H" series
- All models are 80% thermally efficient
- Blower performance up to 3.0” W.C.
- DX or chilled water section with factory installed coil
- Building management system compatible controls
- Safety control devices (Smoke detectors and gas safety switches)
- Input ranges from 75,000 to 1,200,000 Btu/Hr
Easy Installation
- Separate line and low voltage terminal strips (premium units) or low voltage terminal connections (standard units).
- Dead front disconnect switches
Easy to Service
- Job specific wiring diagrams
- Gas manifold positioned to allow for easy burner/pilot access
- Design provides simplified heat exchanger removal
- Gas manifold designed for easy orifice inspection
 www.modine.com |
 |
|
 |
|
|
Hot Dawg Heater
Low-Profile, Gas-Fired Residential Garage Heaters
- Available in 30,000, 45,000, 60,000 & 75,000 Btu/Hr inputs natural gas or propane fueled
- Your choice, power-exhausted or separated-combustion
- Lightweight, saves space with close-to-ceiling mount
- Sealed, permanently lubricated motor for trouble-free dependability
- Quiet operation
Easy Installation
- Simplified installation with standard gas and elecricity knockouts, field wiring connections, two bracket mounting and power exhaust
Easy to Service
- 10 year warranty on heat exchanger
 www.modine.com |
 |
|
 |
|